Zum Kern der Offenlegung springen

Disclosure-BibliothekPraxisleitfaden für jede Berichtsoffenlegung

GRI 103: Energy·Disclosure GRI 103-2

Energy consumption and self-generation within the organization

Praxisleitfaden für die Erstellung dieser Offenlegung. Mit dieser Karte bestimmen Sie die vorzubereitenden Angaben, prüfen Aussagen und ordnen die Nachweise. Für die genauen Anforderungen ziehen Sie stets die offizielle Global Reporting Initiative-Quelle heran.

Rechtsstatus

GRI 103: Energy 2025 is effective for reports or other materials published on or after 1 January 2027, with earlier adoption encouraged.

Veröffentlichter Steckbrief

Zuletzt geprüft am 2026-07-30
RK Geprüft von Dr Ross KurinkoLinkedIn Strategic ESG Advisor · IFRS S1 & S2 / GRI / ESRS expert GRI Certified Global Trainer · PhD, University of Cambridge · ESG-AI expert 15+ years on FTSE 100 & Fortune Global 500 disclosures Canary Wharf, London LRA-Lehrmaterial · Nicht von Global Reporting Initiative herausgegeben oder gebilligt

Standard

GRI 103: Energy

Disclosure GRI 103-2 · 2025

Gültig ab

2027-01-01

Offizielle Quelle: Öffnen ↗

Zuletzt geprüft

2026-07-30

LRA-Lehrmaterial · Nicht von Global Reporting Initiative herausgegeben oder gebilligt

Kern der Offenlegung

Disclosure 103-2 requires an organization to report its fuel consumption, purchased electricity, heating, cooling and steam, self-generated renewable energy consumed within the organization, and self-generated energy sold. The information must be reported in joules, watt-hours or appropriate multiples and supported by the specified source, energy-form and activity breakdowns.

For fuel consumption, the organization must report the total and break it down between renewable and non-renewable energy sources. It must also report the activities in which fuel is consumed for every renewable and non-renewable energy source. The activity breakdown should therefore cover fossil fuels as well as renewable fuels.

Fuel consumption includes fuels purchased by the organization and fuels it generates itself, such as extracted oil and gas or biofuel produced from biomass owned or controlled by the organization. Purchased and self-generated fuels can be reported separately as additional information.

Where the organization consumes fuel to generate electricity or heat and then uses the generated energy internally, the energy must be counted once as fuel consumption. The generated electricity or heat must not be added again as self-generated renewable energy consumption.

The organization must report total purchased electricity, heating, cooling and steam and break the total down between renewable and non-renewable sources. For each renewable and non-renewable source, it must separately report electricity, heating, cooling and steam consumption. Purchased energy includes energy indirectly acquired and consumed, such as electricity consumed by the organization as a tenant.

The organization must report total self-generated renewable electricity, heating, cooling and steam consumed within the organization. This total must be broken down by energy form, by the activity in which the energy is consumed and by each renewable energy source.

Self-generated renewable electricity whose associated contractual attributes have been sold must not be reported as self-generated renewable electricity consumed by the organization.

The organization must report total self-generated electricity, heating, cooling and steam sold. It must break the total down between renewable and non-renewable sources and separately report each energy form for each source.

Where self-generated renewable electricity is sold, the organization should state whether the associated contractual instruments were also sold and should distinguish renewable electricity sold with contractual instruments from electricity sold while the organization retained the attributes.

The organization must report whether contractual instruments were used to disclose purchased electricity, heating, cooling or steam. If they were used, it must describe how the instruments meet the applicable quality criteria for accuracy and consistency.

Contractual instruments must convey a unique greenhouse gas emission-rate attribute, be tracked and redeemed, retired or cancelled on behalf of the organization, be issued and redeemed as close as possible to the relevant consumption period, and be sourced from the same market in which they are applied.

The organization should state whether purchased renewable electricity was calculated using grid-average, location-based information or contractual, market-based information. It should identify how electricity is purchased from the grid, the relevant grid mix and the types of contractual instruments used.

For each contractual-instrument type, the organization should report the amount and percentage of total purchased electricity covered. Additional information can include the generation facility’s commissioning or repowering date, government support, contract length and whether the contract preceded the investment decision to build the facility.

Energy consumed or sold through carriers or storage systems, such as hydrogen or batteries, must be classified according to its primary energy source. The organization should provide contextual information on that primary source and any relevant subsidies or contractual instruments.

The organization must report the standards, methodologies, assumptions and calculation tools used and identify the sources of its energy conversion factors. It should explain why these methods and factors were selected, apply factors consistently and use fuel-specific factors that best represent the actual energy content.

As additional information, the organization can report total energy consumption as the sum of fuel consumption, purchased energy and self-generated renewable energy consumed. It can report total net energy consumption by subtracting self-generated energy sold from that total. Contractual-instrument volumes are subsets of purchased energy and must not be added again.

Where it supports transparency or comparability, the organization can provide additional breakdowns by business unit, facility or country. Where required information cannot be reported, it should apply the relevant reason for omission in accordance with GRI 1 rather than presenting a selected population as the complete organizational total.

Dieses LRA-Lehrmaterial unterstützt die Erstellung der Offenlegung. Für die genauen Anforderungen ziehen Sie stets die offizielle Global Reporting Initiative-Quelle heran.

Bevor Sie beginnen

Bevor Sie beginnen

Eine kurze Checkliste, bevor Sie diese Offenlegung erstellen — haken Sie jeden Punkt ab, sobald er geklärt ist.

Vorbereitung

Wichtige vorzubereitende Angaben

Vorbereitungsfeld Was zu erfassen ist Nachweishinweis Verantwortlich
Required energy totals and units Disclosure 103-2 requires an organization to report its fuel consumption, purchased electricity, heating, cooling and steam, self-generated renewable energy consumed within the organization, and self-generated energy sold. The information must be reported in joules, watt-hours or appropriate multiples and supported by the specified source, energy-form and activity breakdowns. Approved source records, calculation files, reconciliations and review evidence supporting required energy totals and units. Energy / Operations / Sustainability reporting
Fuel total, source and activity breakdown For fuel consumption, the organization must report the total and break it down between renewable and non-renewable energy sources. It must also report the activities in which fuel is consumed for every renewable and non-renewable energy source. The activity breakdown should therefore cover fossil fuels as well as renewable fuels. Fuel consumption includes fuels purchased by the organization and fuels it generates itself, such as extracted oil and gas or biofuel produced from biomass owned or controlled by the organization. Purchased and self-generated fuels can be reported separately as additional information. Where the organization consumes fuel to generate electricity or heat and then uses the generated energy internally, the energy must be counted once as fuel consumption. The generated electricity or heat must not be added again as self-generated renewable energy consumption. Approved source records, calculation files, reconciliations and review evidence supporting fuel total, source and activity breakdown. Energy / Operations / Sustainability reporting
Purchased electricity, heating, cooling and steam The organization must report total purchased electricity, heating, cooling and steam and break the total down between renewable and non-renewable sources. For each renewable and non-renewable source, it must separately report electricity, heating, cooling and steam consumption. Purchased energy includes energy indirectly acquired and consumed, such as electricity consumed by the organization as a tenant. Approved source records, calculation files, reconciliations and review evidence supporting purchased electricity, heating, cooling and steam. Energy Procurement / Sustainability reporting
Self-generated renewable energy consumed The organization must report total self-generated renewable electricity, heating, cooling and steam consumed within the organization. This total must be broken down by energy form, by the activity in which the energy is consumed and by each renewable energy source. Self-generated renewable electricity whose associated contractual attributes have been sold must not be reported as self-generated renewable electricity consumed by the organization. Approved source records, calculation files, reconciliations and review evidence supporting self-generated renewable energy consumed. Energy / Operations / Sustainability reporting
Self-generated energy sold The organization must report total self-generated electricity, heating, cooling and steam sold. It must break the total down between renewable and non-renewable sources and separately report each energy form for each source. Where self-generated renewable electricity is sold, the organization should state whether the associated contractual instruments were also sold and should distinguish renewable electricity sold with contractual instruments from electricity sold while the organization retained the attributes. Approved source records, calculation files, reconciliations and review evidence supporting self-generated energy sold. Energy / Operations / Sustainability reporting
Contractual instruments and quality criteria The organization must report whether contractual instruments were used to disclose purchased electricity, heating, cooling or steam. If they were used, it must describe how the instruments meet the applicable quality criteria for accuracy and consistency. Contractual instruments must convey a unique greenhouse gas emission-rate attribute, be tracked and redeemed, retired or cancelled on behalf of the organization, be issued and redeemed as close as possible to the relevant consumption period, and be sourced from the same market in which they are applied. Approved source records, calculation files, reconciliations and review evidence supporting contractual instruments and quality criteria. Energy Procurement / Sustainability reporting
Purchased-electricity calculation basis and coverage The organization should state whether purchased renewable electricity was calculated using grid-average, location-based information or contractual, market-based information. It should identify how electricity is purchased from the grid, the relevant grid mix and the types of contractual instruments used. For each contractual-instrument type, the organization should report the amount and percentage of total purchased electricity covered. Additional information can include the generation facility’s commissioning or repowering date, government support, contract length and whether the contract preceded the investment decision to build the facility. Approved source records, calculation files, reconciliations and review evidence supporting purchased-electricity calculation basis and coverage. Energy Procurement / Sustainability reporting
Energy carriers and storage Energy consumed or sold through carriers or storage systems, such as hydrogen or batteries, must be classified according to its primary energy source. The organization should provide contextual information on that primary source and any relevant subsidies or contractual instruments. Approved source records, calculation files, reconciliations and review evidence supporting energy carriers and storage. Energy / Operations / Sustainability reporting
Standards, methods and conversion factors The organization must report the standards, methodologies, assumptions and calculation tools used and identify the sources of its energy conversion factors. It should explain why these methods and factors were selected, apply factors consistently and use fuel-specific factors that best represent the actual energy content. Approved source records, calculation files, reconciliations and review evidence supporting standards, methods and conversion factors. Energy / Operations / Sustainability reporting
Optional gross and net totals, breakdowns and omissions As additional information, the organization can report total energy consumption as the sum of fuel consumption, purchased energy and self-generated renewable energy consumed. It can report total net energy consumption by subtracting self-generated energy sold from that total. Contractual-instrument volumes are subsets of purchased energy and must not be added again. Where it supports transparency or comparability, the organization can provide additional breakdowns by business unit, facility or country. Where required information cannot be reported, it should apply the relevant reason for omission in accordance with GRI 1 rather than presenting a selected population as the complete organizational total. Approved source records, calculation files, reconciliations and review evidence supporting optional gross and net totals, breakdowns and omissions. Energy / Operations / Sustainability reporting
+ Teilelemente von GRI 103-2 anzeigen (LRA-Arbeitscheckliste)

So bereiten Sie es vor

Use the complete organisational reporting perimeter. Report every required energy stream and source, or apply the relevant GRI 1 reason for omission rather than presenting a selected population as complete.
Collect and reconcile the records for: Required energy totals and units; Fuel total, source and activity breakdown; Purchased electricity, heating, cooling and steam; Self-generated renewable energy consumed; Self-generated energy sold; Contractual instruments and quality criteria; Purchased-electricity calculation basis and coverage; Energy carriers and storage; Standards, methods and conversion factors; Optional gross and net totals, breakdowns and omissions.
Apply contractual-instrument fields where instruments are used and prevent double counting between fuel inputs, generated energy, purchased energy and contractual-instrument subsets.
Draft the response using the defined terms shown in the disclosure focus; do not substitute broader internal labels.
Review the final wording against every requirement and the supporting governance or data records before sign-off.

Daten anfordern

Request the disclosure evidence

Übersetzen Sie die Offenlegung in eine interne Geschäftsfrage — und passen Sie diese dann an die Sprache Ihrer Organisation an.

Provide the organisational energy inventory; fuel, purchased-energy, self-generated consumption and sales registers; source, form and activity breakdowns; contractual-instrument register and quality evidence; grid basis; carrier classification; conversion-factor sources and calculation files.

Use the organisation's own role and document names, but preserve the defined GRI terms and the scope described above.

Bessere Anfrage

Provide the organisational energy inventory; fuel, purchased-energy, self-generated consumption and sales registers; source, form and activity breakdowns; contractual-instrument register and quality evidence; grid basis; carrier classification; conversion-factor sources and calculation files.

Offenlegung entwerfen

Notizen, die aus Daten eine Offenlegung machen

LRA-Schulungsvorlagen — passen Sie sie an Ihre Organisation an und prüfen Sie vor der Freigabe die offizielle Quelle.

Methodenhinweis

Count fuel used to generate internally consumed energy once as fuel. Classify carriers by primary energy source and keep contractual-instrument volumes as subsets rather than adding them to purchased energy.

Kontexthinweis

Optional total energy and net-energy calculations and facility, business-unit or country breakdowns can improve comparability but do not replace the required organisational totals and detailed breakdowns.

Download-Center

Werkzeuge & Formulare zur Vorbereitung

Professionelle Vorbereitungswerkzeuge für GRI 103-2 — kostenlos mit einer LRA Community-Mitgliedschaft. Einmal registrieren (kostenlos) und alle Downloads sind frei — zusammen mit der Disclosure-Bibliothek, den Vorlagen und dem LRA KI-Assistenten.

Kostenlos · Community-Mitglieder

Prüfungsbereitschaft

Prüfen Sie zu jeder Aussage die Nachweise

Aussage Risiko Zu prüfende Nachweise
Required energy totals and units is reported accurately and completely.The response omits, misclassifies or overstates required energy totals and units.Approved source records, calculation files, reconciliations and review evidence supporting required energy totals and units.
Fuel total, source and activity breakdown is reported accurately and completely.The response omits, misclassifies or overstates fuel total, source and activity breakdown.Approved source records, calculation files, reconciliations and review evidence supporting fuel total, source and activity breakdown.
Purchased electricity, heating, cooling and steam is reported accurately and completely.The response omits, misclassifies or overstates purchased electricity, heating, cooling and steam.Approved source records, calculation files, reconciliations and review evidence supporting purchased electricity, heating, cooling and steam.
Self-generated renewable energy consumed is reported accurately and completely.The response omits, misclassifies or overstates self-generated renewable energy consumed.Approved source records, calculation files, reconciliations and review evidence supporting self-generated renewable energy consumed.
Self-generated energy sold is reported accurately and completely.The response omits, misclassifies or overstates self-generated energy sold.Approved source records, calculation files, reconciliations and review evidence supporting self-generated energy sold.
Contractual instruments and quality criteria is reported accurately and completely.The response omits, misclassifies or overstates contractual instruments and quality criteria.Approved source records, calculation files, reconciliations and review evidence supporting contractual instruments and quality criteria.
Purchased-electricity calculation basis and coverage is reported accurately and completely.The response omits, misclassifies or overstates purchased-electricity calculation basis and coverage.Approved source records, calculation files, reconciliations and review evidence supporting purchased-electricity calculation basis and coverage.
Energy carriers and storage is reported accurately and completely.The response omits, misclassifies or overstates energy carriers and storage.Approved source records, calculation files, reconciliations and review evidence supporting energy carriers and storage.
Standards, methods and conversion factors is reported accurately and completely.The response omits, misclassifies or overstates standards, methods and conversion factors.Approved source records, calculation files, reconciliations and review evidence supporting standards, methods and conversion factors.
Optional gross and net totals, breakdowns and omissions is reported accurately and completely.The response omits, misclassifies or overstates optional gross and net totals, breakdowns and omissions.Approved source records, calculation files, reconciliations and review evidence supporting optional gross and net totals, breakdowns and omissions.

Vorzubereitendes Nachweispaket

Häufige Lücken in der Berichterstattung

Breaking fuel activity down only for renewable fuels.
Combining electricity, heating, cooling and steam in one purchased-energy line.
Double counting fuel and internally generated electricity or heat.
Reporting self-generated renewable electricity after selling its attributes.
Reporting contractual instruments without their quality criteria and coverage.
Using a generic conversion factor without a documented source and rationale.
✓ LRA KI-Assistent · Mit menschlicher Kontrolle
Dr Ross Kurinko

Fragen Sie den Study-Studio-KI-Assistenten zu dieser Offenlegung

Erhalten Sie praxisnahe Antworten für Ihren Berichtskontext. Die ersten beiden Antworten sind kostenlos — treten Sie der LRA Community kostenlos bei, um ohne Limit weiterzumachen.

Ausprobieren Wie bereite ich GRI 103-2 vor? Welche Daten muss ich erheben? Welche Fehler sollte ich vermeiden?
2 kostenlose Antworten

Verweise auf das Rahmenwerk

Einschlägige GRI-Anforderungen und verwandte Offenlegungen

Verfügbare Verweise auf das Rahmenwerk und benachbarte Offenlegungen, die für diese Anforderung relevant sind.

GRI

GRI 103-2

innerhalb von GRI 103: Energy

Offizielle Quelle öffnen →

Verwandtes & Entdecken

Mehr in GRI 103 → Gesamten Katalog durchsuchen → Startseite der Disclosure-Bibliothek → Alle Offenlegungen durchsuchen →

Tiefer einsteigen · GRI 103-2

Lernen Sie, diese Offenlegung durchgängig zu erstellen

This guide covers one disclosure. The GRI Standards Certified Training — taken as a bundle with an ESRS course — walks the full workflow: datapoints, evidence, drafting and assurance, with exercises on your own data.

Available as Guided Flex, Live Cohort, 1:1 Expert Mentorship or Corporate Programme.

Explore GRI training (ESRS bundle) →
Wie diese Bibliothek entsteht 312 veröffentlichte Berichte indexiert 63.171 Seiten mit seitengenauen Fundstellen 272 von Praktikern erstellte Disclosure-Karten
/de/knowledge-hub/disclosure-cards/gri-103-2/