Ga naar de kern van de disclosure

DisclosurebibliotheekPraktische leidraad voor elke rapportage-disclosure

GRI 302: Energy·Disclosure GRI 302-2

Energy consumption outside of the organization

Praktische leidraad voor het opstellen van deze disclosure. Gebruik deze kaart om te bepalen welke informatie u voorbereidt, om beweringen te toetsen en om onderbouwend bewijs te ordenen. Raadpleeg voor de exacte vereisten altijd de officiële Global Reporting Initiative-bron.

Juridische status

GRI 302: Energy 2016 remains applicable for reports or other materials published up to 31 December 2026. For reporting published on or after 1 January 2027, use the corresponding disclosure in GRI 103: Energy 2025.

Gepubliceerd paspoort

Laatst beoordeeld op 2026-08-01
RK Beoordeeld door Dr Ross KurinkoLinkedIn Strategic ESG Advisor · IFRS S1 & S2 / GRI / ESRS expert GRI Certified Global Trainer · PhD, University of Cambridge · ESG-AI expert 15+ years on FTSE 100 & Fortune Global 500 disclosures Canary Wharf, London Educatief materiaal van LRA · Niet uitgegeven of goedgekeurd door Global Reporting Initiative

Standaard

GRI 302: Energy

Disclosure GRI 302-2 · 2016

Van kracht

2018-07-01

Officiële bron: Openen ↗

Laatst beoordeeld

2026-08-01

Educatief materiaal van LRA · Niet uitgegeven of goedgekeurd door Global Reporting Initiative

Kern van de disclosure

Disclosure 302-2 requires an organization to report energy consumption outside the organization in joules or multiples, together with the standards, methodologies, assumptions and calculation tools used and the sources of the conversion factors.

Energy consumption outside the organization occurs in upstream and downstream activities associated with the organization’s operations. It is not defined solely by whether energy is consumed away from the organization’s physical sites. For example, energy used by an owned or controlled vehicle can fall within Disclosure 302-1 even when the vehicle operates off-site.

When compiling the disclosure, exclude all energy consumption reported under Disclosure 302-1. Assess potential upstream and downstream activities systematically using documented relevance criteria, including their contribution to anticipated energy consumption, reduction potential, climate-related risks, stakeholder relevance, outsourcing and sector significance.

GRI recommends listing energy consumption with a breakdown by upstream and downstream categories and activities. The categories can be aligned with the GHG Protocol Corporate Value Chain (Scope 3) Standard.

Activity data used for Scope 3 calculations can support the disclosure, but GRI 302-2 reports energy rather than GHG emissions. Use energy-content or activity-to-energy conversion factors and report the result in joules or multiples, not tonnes of CO₂e.

Dit educatieve materiaal van LRA ondersteunt het opstellen van de disclosure. Raadpleeg voor de exacte vereisten altijd de officiële Global Reporting Initiative-bron.

Voordat u begint

Voordat u begint

Een korte checklist voordat u deze disclosure opstelt — vink elk punt af zodra het geregeld is.

Voorbereiding

Belangrijkste voor te bereiden informatie

Voorbereidingsveld Wat vast te leggen Aanwijzing voor bewijs Eigenaar
GRI 302-1 reconciliation Energy streams excluded because they are already reported within the organization. GRI 302-1 workbook and boundary mapping. Sustainability / Energy
Upstream and downstream screening Full assessment of potential value-chain categories and activities. Category screening and significance assessment. Sustainability Reporting
External energy consumption Energy in GJ/TJ for each included activity and the consolidated total. Supplier records, models and source data. Category data owners
Value-chain category Applicable upstream or downstream category. GHG Protocol category mapping. Sustainability Reporting
Relevance criteria Why an activity is included or excluded. Significance methodology and approval record. Sustainability / Risk
Activity data Distance, fuel, electricity, production, sales, use-phase or treatment data. Operational system exports. Procurement / Logistics / Product teams
Primary or estimated data Data-quality classification and primary-data coverage. Supplier files and estimation register. Data owners
Calculation method Method, assumptions, allocation and calculation tool. Methodology document and model. Data Analytics / Sustainability
Conversion factors Energy factors, source, version and period. Factor library and official sources. Sustainability / Energy
Category total Energy consumption by upstream or downstream category. Calculation workbook. Sustainability Reporting
Consolidated total Total energy consumption outside the organization. Category reconciliation. Sustainability Reporting
Renewable/non-renewable split Optional under GRI 302-2; useful for transition to GRI 103. Energy-source classification. Energy / Suppliers
+ Subelementen van GRI 302-2 tonen (LRA-werkchecklist)

Hoe u dit voorbereidt

Disclosure 302-2 requires an organization to report energy consumption outside the organization in joules or multiples, together with the standards, methodologies, assumptions and calculation tools used and the sources of the conversion factors.
Collect and reconcile the records for: GRI 302-1 reconciliation; Upstream and downstream screening; External energy consumption; Value-chain category; Relevance criteria; Activity data; Primary or estimated data; Calculation method; Conversion factors; Category total; Consolidated total; Renewable/non-renewable split.
Apply Disclosure 302-2 when the related topic is material and this disclosure is relevant to the organisation's impacts, or when an applicable GRI Sector Standard identifies it for reporting.
Draft the response using the defined terms shown in the disclosure focus; do not substitute broader internal labels.
Review the final wording against every requirement and the supporting governance or data records before sign-off.

De gegevens opvragen

Request the disclosure evidence

Vertaal de disclosure naar een interne bedrijfsvraag — en pas die daarna aan op het taalgebruik van uw organisatie.

Provide the reporting-period records and reconciliations for Disclosure 302-2: GRI 302-1 reconciliation; Upstream and downstream screening; External energy consumption; Value-chain category; Relevance criteria; Activity data; Primary or estimated data; Calculation method; Conversion factors; Category total; Consolidated total; Renewable/non-renewable split. Include scope, definitions, methods, assumptions, limitations, owners and approvals.

Use the organisation's own role and document names, but preserve the defined GRI terms and the scope described above.

Beter verzoek

Provide the reporting-period records and reconciliations for Disclosure 302-2: GRI 302-1 reconciliation; Upstream and downstream screening; External energy consumption; Value-chain category; Relevance criteria; Activity data; Primary or estimated data; Calculation method; Conversion factors; Category total; Consolidated total; Renewable/non-renewable split. Include scope, definitions, methods, assumptions, limitations, owners and approvals.

Stel uw disclosure op

Notities die gegevens tot een disclosure maken

LRA-trainingssjablonen — pas ze aan op uw organisatie en controleer de officiële bron vóór goedkeuring.

Methodenotitie

Activity data used for Scope 3 calculations can support the disclosure, but GRI 302-2 reports energy rather than GHG emissions. Use energy-content or activity-to-energy conversion factors and report the result in joules or multiples, not tonnes of CO₂e.

Contextnotitie

Keep mandatory Requirements, GRI recommendations and additional LRA preparation controls clearly distinguished. Use a GRI 1 reason for omission where an applicable requirement cannot be reported.

Downloadcentrum

Hulpmiddelen en formulieren voor de voorbereiding

Professionele voorbereidingshulpmiddelen voor GRI 302-2 — gratis met een LRA Community-lidmaatschap. Registreer u eenmalig (gratis) en alle downloads komen vrij, samen met de Disclosure-bibliotheek, de sjablonen en de LRA AI-assistent.

Gratis · Community-leden

Assurance-gereedheid

Controleer bij elke bewering het bewijs

Bewering Risico Te controleren bewijs
GRI 302-1 reconciliation is reported accurately and completely.The response omits, misclassifies or overstates gri 302-1 reconciliation.GRI 302-1 workbook and boundary mapping.
Upstream and downstream screening is reported accurately and completely.The response omits, misclassifies or overstates upstream and downstream screening.Category screening and significance assessment.
External energy consumption is reported accurately and completely.The response omits, misclassifies or overstates external energy consumption.Supplier records, models and source data.
Value-chain category is reported accurately and completely.The response omits, misclassifies or overstates value-chain category.GHG Protocol category mapping.
Relevance criteria is reported accurately and completely.The response omits, misclassifies or overstates relevance criteria.Significance methodology and approval record.
Activity data is reported accurately and completely.The response omits, misclassifies or overstates activity data.Operational system exports.
Primary or estimated data is reported accurately and completely.The response omits, misclassifies or overstates primary or estimated data.Supplier files and estimation register.
Calculation method is reported accurately and completely.The response omits, misclassifies or overstates calculation method.Methodology document and model.
Conversion factors is reported accurately and completely.The response omits, misclassifies or overstates conversion factors.Factor library and official sources.
Category total is reported accurately and completely.The response omits, misclassifies or overstates category total.Calculation workbook.
Consolidated total is reported accurately and completely.The response omits, misclassifies or overstates consolidated total.Category reconciliation.
Renewable/non-renewable split is reported accurately and completely.The response omits, misclassifies or overstates renewable/non-renewable split.Energy-source classification.

Voor te bereiden bewijsdossier

Veelvoorkomende hiaten in de rapportage

Reporting Scope 3 GHG emissions instead of energy consumption outside the organisation.
Defining outside the organisation only by physical location.
Using internal labels in place of the defined GRI terms.
Leaving a required preparation field unsupported by traceable evidence.
Treating GRI recommendations as mandatory requirements or mandatory requirements as optional.
Publishing estimates, exclusions or partial scope without methods, assumptions and the applicable reason for omission.
✓ LRA AI-assistent · Met menselijke controle
Dr Ross Kurinko

Vraag de Study Studio AI-assistent naar deze disclosure

Krijg praktische antwoorden voor uw rapportagecontext. Uw eerste twee antwoorden zijn gratis — word gratis lid van LRA Community om zonder limiet door te gaan.

Probeer Hoe bereid ik GRI 302-2 voor? Welke gegevens moet ik verzamelen? Welke fouten moet ik vermijden?
2 gratis antwoorden

Verwijzingen naar het raamwerk

Relevante GRI-vereisten en verwante disclosures

Beschikbare verwijzingen naar het raamwerk en aanpalende disclosures die relevant zijn voor deze vereiste.

GRI

GRI 302-2

binnen GRI 302: Energy

Officiële bron openen →

Gerelateerd & verkennen

Meer in GRI 302 → Volledige catalogus bekijken → Home van de Disclosure-bibliotheek → Zoeken in alle disclosures →

Verder verdiepen · GRI 302-2

Leer deze disclosure van begin tot eind op te stellen

This guide covers one disclosure. The GRI Standards Certified Training — taken as a bundle with an ESRS course — walks the full workflow: datapoints, evidence, drafting and assurance, with exercises on your own data.

Available as Guided Flex, Live Cohort, 1:1 Expert Mentorship or Corporate Programme.

Explore GRI training (ESRS bundle) →
Hoe deze bibliotheek is opgebouwd 312 gepubliceerde rapporten geïndexeerd 63.171 pagina’s met verwijzingen op paginaniveau 272 door practitioners gemaakte Disclosurekaarten
/nl/knowledge-hub/disclosure-cards/gri-302-2/